Try “dust collector,” “installations,” or “welding.”

Application

Combustible Dust

Spark detection, isolation valves, and explosion venting for facilities generating combustible dust under NFPA 61, 654, 68, and 69. Our Spark & Explosion Control line includes Raptor spark detection and extinguishing systems, Boss Process rotary airlock valves, and Vigilex/Vigiflap/Vigispace venting and isolation equipment, and pairs with Wet Downdraft Tables where a wet capture method is the safer choice for a given dust type. See also our Safety guide to Combustible Dust for the underlying hazard classifications.

Recommended Equipment

No products tagged with this application yet.

FAQ

Common Questions

A dry downdraft table pulls dust and fume through dry filter media, while a wet downdraft table (like our Storm series) draws air through a water bath, which captures sparks and combustible dust before they reach a filter. Wet tables are generally the safer choice for processes that generate hot sparks, aluminum or magnesium dust, or other combustible fines where a dry filter would pose an ignition risk.

Requirements vary by state and local jurisdiction, but combustible dust applications are generally subject to NFPA 61, 654, 68, and 69, and OSHA's general duty clause even where a specific combustible-dust standard hasn't been formally adopted. Our System Audits & Testing service can help document that a new or existing system meets applicable standards; see our Safety section for a plain-English overview.

A spark detection and extinguishing system (like our Raptor line) continuously monitors ductwork for sparks or embers generated upstream by grinding, cutting, or other hot processes, and automatically extinguishes them with a water mist before they reach a filter or collector where they could ignite accumulated dust. It's typically recommended wherever a process both generates sparks and feeds a dry dust collection system.

An explosion vent (like our Vigilex domed or flameless vent panels) is designed to relieve pressure safely to the outside of a vessel if a dust explosion occurs inside it. An explosion isolation valve (like our Vigiflap valves) is designed to stop flame and pressure from traveling through ductwork from one piece of equipment to another, preventing a secondary explosion elsewhere in the system. Most combustible-dust systems use both as part of a layered protection strategy.

Not sure which system you need?

Get a free consultation with a Sledge Tech filtration engineer — most quotes turned around in 24 hours.

Request A Quote
Request Quote