Try “dust collector,” “installations,” or “welding.”

Downdraft Tables

3X4 Downdraft Tables

Eliminate dangerous fumes and dust produced by welding, grinding and deburring at-source with Sledge Tech's 3X4 Downdraft Table. OSHA-compliant. Learn more.

Up to 4300 CFM of air flow
Max air flow
48” x 36” worksurface
Worksurface
High capture face velocity (450 FPM)
Capture face velocity
5.0 HP three-phase [230/460/575V] motor
Motor
Overview

3X4 Downdraft Tables

Durable and reliable, the Sledge Tech 3' X 4' Downdraft Table is designed to handle industrial duty applications. Harmful fumes, smoke and dust are captured right at the source, before they can enter your breathing space, so indoor air quality remains uncompromised. Whether you weld, grind, debur, cut, sand, finish, solder, paint or mix, the Sledge Tech 3' X 4' Downdraft Table is a versatile all-in-one solution.

The 3' X 4' Downdraft Table comes crafted with multi-stage spark arrestance baffles for added safety, along with industrial swivel casters and a push-button, reverse-pulse filter cleaning system to reduce maintenance. This downdraft table generates up to 4300 CFM of air flow powered by a 5.0 HP three-phase [230/460/575V] motor.

With many options and accessories available, the Sledge Tech 3' X 4' Downdraft Table can be custom built to your specific needs.

Up to 4300 CFM of air flow
of air flow at peak performance

High capture face velocity (450 FPM)
capture face velocity keeps fumes out of the breathing zone

Compliant with OSHA guidelines for safe capture of dust, smoke and weld fumes
compliant capture of dust, smoke and weld fumes
Specifications

Features, Benefits & Technical Specs

  • 48” x 36” worksurface
  • Up to 4300 CFM of air flow
  • High capture face velocity (450 FPM)
  • Automatic self-cleaning system
  • Multi-stage spark arrestance baffling
  • Dust drawer for simple servicing
  • Compliant with OSHA guidelines for safe capture of dust, smoke and weld fumes
  • Low maintenance
  • Capture-at-source for cleaner air
  • Four (4) swivel casters for easier movement
  • Minihelic gauge
  • Side walls
  • Dual HEPA afterfilter with frame
Worksurface48” x 36” worksurface
Max air flowUp to 4300 CFM of air flow
Capture face velocityHigh capture face velocity (450 FPM)
Motor5.0 HP three-phase [230/460/575V] motor
Filter cleaningAutomatic self-cleaning system
Spark protectionMulti-stage spark arrestance baffling
ComplianceCompliant with OSHA guidelines for safe capture of dust, smoke and weld fumes
Download Full Product Brochure →
FAQ

Common Questions

Required CFM depends on the size of the work surface and the capture velocity needed for your process — heavier fume-generating work like welding typically needs more air movement per square foot than light sanding. As a general reference, our own Downdraft Tables line ranges from a 1,200 CFM Mini model up to 6,300 CFM on our largest 3'x8' and 4'x8' tables. Our team can size a table to your specific application; contact us for a recommendation.

A dry downdraft table pulls dust and fume through dry filter media, while a wet downdraft table (like our Storm series) draws air through a water bath, which captures sparks and combustible dust before they reach a filter. Wet tables are generally the safer choice for processes that generate hot sparks, aluminum or magnesium dust, or other combustible fines where a dry filter would pose an ignition risk.

A wet scrubber routes contaminated air through a water bath or spray chamber rather than dry filter media, which makes it well suited to overspray from spray painting, and to dusts that are combustible, sticky, or otherwise poor candidates for dry filtration. Our Camfil Handte Wet Scrubbers line includes Vortex, Vortex Dual, and Venturi models for different airflow and contaminant loads.

Hexavalent chromium is generated when welding or cutting stainless steel and other chromium alloys, and OSHA regulates exposure under 29 CFR 1910.1026. Source capture with a properly sized downdraft table or fume extraction system is the primary engineering control; see our Safety guide to Hexavalent Chromium for exposure limits and a fuller overview.

Related Products

You May Also Need

2X4 Downdraft Tables

2X4 Downdraft Tables

Eliminate dangerous fumes and dust produced by welding, grinding and deburring at-source with Sledge Tech's 2X4…

Learn More →
Up to 5050 CFM of air flow 3X6 Downdraft Tables

3X6 Downdraft Tables

Eliminate dangerous fumes and dust produced by welding, grinding and deburring at-source with Sledge Tech's 3X6…

Learn More →
Up to 6300 CFM of air flow 3X8 Downdraft Tables

3X8 Downdraft Tables

Eliminate dangerous fumes and dust produced by welding, grinding and deburring at-source with Sledge Tech's 3X8…

Learn More →
Up to 4300 CFM of air flow 4X4 Downdraft Tables

4X4 Downdraft Tables

Eliminate dangerous fumes and dust produced by welding, grinding and deburring at-source with Sledge Tech's 4X4…

Learn More →

Ready to spec your system?

Get a free consultation with a Sledge Tech filtration engineer — most quotes turned around in 24 hours.

Request A Quote
Request Quote